Roofing Sheet Thickness and Coating Explained: BMT, TCT, GI and Galvalume

Two roofing sheet quotations can both say “0.50 mm colour-coated sheet” and still be very different products. The difference is usually in how the thickness is measured and what is under the paint. This guide explains the terms you will see on roofing sheet quotations in India (BMT, TCT, GI, galvalume, Z and AZ coating classes) so you can compare offers on equal terms.

BMT vs TCT: the thickness trap

A colour-coated roofing sheet is a sandwich: a steel base, a metallic coating (zinc or aluminium-zinc) on both sides, and paint layers on top.

  • BMT (Base Metal Thickness) is the thickness of the steel alone, excluding the coatings. It is the steel that carries load, resists denting and holds the screws.
  • TCT (Total Coated Thickness) is the overall thickness including the metallic coating and paint. Some manufacturers use “APT” (after-painted thickness) for the finished painted sheet.

Because coatings and paint add thickness, a sheet quoted as 0.50 mm TCT has a thinner steel core than a sheet quoted as 0.50 mm BMT. When comparing quotations, ask for the BMT, and make sure every offer states thickness on the same basis.

Metallic coating: GI vs galvalume

The metallic coating protects the steel from corrosion, including at cut edges and scratches. Two coatings dominate the Indian market.

Galvanised (GI): zinc coating

Galvanised steel sheet is coated with zinc by a continuous hot-dip process. In India, hot-dip zinc-coated sheet is covered by IS 277. Coating is specified by coating mass in g/m², the total for both surfaces. For example, a Z275 or “275 GSM” coating means 275 g/m² of zinc in total, across both sides.

Galvalume: aluminium-zinc coating

Galvalume (also called aluzinc or AZ coating) uses an alloy of about 55% aluminium with zinc. In India, hot-dip aluminium-zinc coated sheet is covered by IS 15961, with coating classes such as AZ70, AZ100, AZ150 and AZ200. The number is the coating mass in g/m², again across both surfaces. Pre-painted (colour-coated) galvalume sheet is covered by IS 15965.

Which coating should you choose?

  • Compare coatings by both type and mass. “Galvalume” alone, without an AZ class, is not a complete specification.
  • Higher coating mass generally means longer protection in the same environment.
  • Galvalume is widely used for industrial roofing and cladding. Galvanised sheet remains common for purlins, decking and many general applications.
  • The environment decides the coating needed: coastal, chemical, fertiliser, or high-humidity sites need more protection than a dry inland site. Ask the sheet manufacturer for its recommendation for your location.

The paint system

On colour-coated sheets, the paint layer gives colour and adds a barrier over the metallic coating. Quotations should state the paint type (for example regular polyester, or higher-performance systems) and the dry film thickness on the top and back surfaces. A cheaper sheet sometimes saves cost with thinner paint or a thinner back coat.

How thick should a roofing sheet be?

There is no single right thickness. The designer selects the sheet based on purlin spacing, wind load, roof access for maintenance, and the sheet profile’s load tables. Thinner sheets may suit small sheds and canopies, while large industrial roofs and walls generally use heavier sheets. Follow the thickness and profile specified on your drawings, and confirm whether that figure is BMT or TCT.

Checklist: what to put in a roofing sheet enquiry

Item Example of what to state
Thickness and basis 0.50 mm BMT (not just “0.50 mm”)
Substrate and coating Galvalume AZ150, or GI with coating mass in g/m²
Steel grade / yield strength As per design or the manufacturer’s standard
Paint system and colour Paint type, top and back coat thickness, colour shade
Profile Trapezoidal / corrugated / standing seam, with cover width
Lengths and quantity Sheet lengths or a cutting list, and total area
Accessories Ridge, flashings, closures, screws, sealant
Site and delivery Location and required date

A complete specification lets you compare quotations fairly. It also protects you from receiving a thinner core or lighter coating than you thought you were buying.

ISERN Industries supplies roofing and wall cladding sheets, standing seam roofing and C and Z purlins from Bagru, Jaipur. If you are choosing a roof system as well as the sheet, see standing seam vs screw-fixed roofing.

Frequently asked questions

What is the difference between BMT and TCT?

BMT is the thickness of the base steel only. TCT is the total thickness including the metallic coating and paint. For the same stated number, a TCT sheet has a thinner steel core than a BMT sheet.

What does AZ150 mean?

AZ150 is an aluminium-zinc (galvalume) coating class with a coating mass of 150 g/m², counted across both surfaces of the sheet. In India, AZ coating classes are covered by IS 15961.

Is galvalume better than GI for roofing?

Galvalume is widely used for industrial roofing and cladding. The comparison depends on coating mass as well as type, and on the site environment, so compare the full specification rather than the coating name alone.

Need a roofing quotation? Send your specification or drawings to ISERN, call +91 97733 52377 or email [email protected].

Scroll to top